Measurement of LYSO Crystal Light Output and Energy Resolution Improvement with Acid Etching
Yükleniyor...
Tarih
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Elsevier Ltd
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
In this study, we investigated the impact of chemical etching on the light output and energy resolution of LYSO scintillators using simple, affordable laboratory equipment. We found that etching with phosphoric acid at temperatures between 180 °C and 190 °C improved the light output and energy resolution compared to mechanically polished crystals, even after minimal etching times. Our results show that with 7.5 min of chemical etching, the light output increase rate is 45.7%, and the relative energy resolution improvement is 12%.
Açıklama
We would like to thank Bilal Cakir, Istanbul Sabahattin Zaim and Istinye University chemistry laboratory staff for their support in pro- viding equipment.
Anahtar Kelimeler
Chemical etching, Scintillator light output, Scintillator polishing, Surface treatment
Kaynak
Applied Radiation and Isotopes
WoS Q Değeri
Scopus Q Değeri
Cilt
199
Sayı
Künye
Kolcu, O. B., Iren, E., Yetkin, T., Özok, F., & Erduran, M. N. (2023). Measurement of LYSO crystal light output and energy resolution improvement with acid etching. Applied Radiation and Isotopes, 199, 110902.