Pulse pile-up identification and reconstruction for liquid scintillator based neutron detectors

dc.contributor.authorLuo, X. L.
dc.contributor.authorModamio, Victor
dc.contributor.authorNyberg, Johan
dc.contributor.authorValiente-Dobon, J. J.
dc.contributor.authorNishada, Q.
dc.contributor.authorde Angelis, G.
dc.contributor.authorAgramunt, J.
dc.contributor.authorEgea, F. J.
dc.contributor.authorErduran, Mustafa Nizamettin
dc.contributor.authorErturk, Sefa
dc.contributor.authorde France, Gilles
dc.contributor.authorGadea, A.
dc.contributor.authorGonzalez, Vicente
dc.contributor.authorGoasduff, Alain
dc.contributor.authorHüyük, Tayfun
dc.contributor.authorJaworski, Grzegorz
dc.contributor.authorMoszynski, Marek
dc.contributor.authorDi Nitto, Antonio
dc.contributor.authorPalacz, Marcin
dc.contributor.authorSöderström, Par-Anders
dc.contributor.authorSanchis, Enrique
dc.contributor.authorTriossi, A.
dc.contributor.authorWadsworth, R.
dc.contributor.authorErduran, Mustafa Nizamettin
dc.date.accessioned2019-08-31T12:10:23Z
dc.date.accessioned2019-08-13T09:37:35Z
dc.date.available2019-08-31T12:10:23Z
dc.date.available2019-08-13T09:37:35Z
dc.date.issued2018en_US
dc.departmentMühendislik ve Doğa Bilimleri Fakültesien_US
dc.descriptionWOS: 000433206800010en_US
dc.description.abstractThe issue of pulse pile-up is frequently encountered in nuclear experiments involving high counting rates, which will distort the pulse shapes and the energy spectra. A digital method of off-line processing of pile-up pulses is presented. The pile-up pulses were firstly identified by detecting the downward-going zero-crossings in the first-order derivative of the original signal, and then the constituent pulses were reconstructed based on comparing the pile-up pulse with four models that are generated by combining pairs of neutron and.. standard pulses together with a controllable time interval. The accuracy of this method in resolving the pile-up events was investigated as a function of the time interval between two pulses constituting a pile-up event. The obtained results show that the method is capable of disentangling two pulses with a time interval among them down to 20 ns, as well as classifying them as neutrons or gamma rays. Furthermore, the error of reconstructing pile-up pulses could be kept below 6% when successive peaks were separated by more than 50 ns. By applying the method in a high counting rate of pile-up events measurement of the NEutron Detector Array (NEDA), it was empirically found that this method can reconstruct the pile-up pulses and perform neutron-gamma discrimination quite accurately. It can also significantly correct the distorted pulse height spectrum due to pile-up events.en_US
dc.description.sponsorshipSwedish Research Council; UK STFC [ST/L005727/1]; Generalitat Valenciana, Spain [PROMETEO/2010/101]; MINECO, Spain [AIC-D-2011-0746, FPA2011-29854, FPA2012-33650]; TUBITAK, Turkey [114F473]en_US
dc.description.sponsorshipThis work was partly funded by the Swedish Research Council, by the UK STFC, under grant ST/L005727/1, by the Generalitat Valenciana, Spain, under grant PROMETEO/2010/101, by MINECO, Spain, under grants AIC-D-2011-0746, FPA2011-29854 and FPA2012-33650, and by TUBITAK, Turkey, under grant 114F473.en_US
dc.identifier.doi10.1016/j.nima.2018.03.078
dc.identifier.endpage65en_US
dc.identifier.issn0168-9002
dc.identifier.issn1872-9576
dc.identifier.orcidAntonio Di Nitto |0000-0002-9319-366Xen_US
dc.identifier.orcidVicente Gonzalez Millan |0000-0001-6014-2586
dc.identifier.orcidTayfun Hüyük |0000-0003-0597-9767
dc.identifier.orcidAndres Gadea |0000-0002-4233-1970
dc.identifier.orcidPar-Anders Soderstrom |0000-0002-9504-2814
dc.identifier.orcidEnrique Sanchis Peris |0000-0002-9689-9131
dc.identifier.orcidGilles de France |0000-0002-7439-1759
dc.identifier.orcidAlain Goasduff |0000-0003-3453-3297
dc.identifier.scopusqualityQ2
dc.identifier.startpage59en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.nima.2018.03.078
dc.identifier.urihttps://hdl.handle.net/20.500.12436/951
dc.identifier.volume897en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorErduran, Mustafa Nizamettin
dc.language.isoen
dc.publisherElsevier Science BVen_US
dc.relation.ispartofNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipmenten_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPile-upen_US
dc.subjectDigitalen_US
dc.subjectFirst-order derivativeen_US
dc.subjectNeutron-gamma discriminationen_US
dc.subjectLiquid scintillatoren_US
dc.titlePulse pile-up identification and reconstruction for liquid scintillator based neutron detectorsen_US
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublicationf15c7b3b-1513-45ba-ba89-0994e82a74cb
relation.isAuthorOfPublication.latestForDiscoveryf15c7b3b-1513-45ba-ba89-0994e82a74cb

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Luo-2018-Pulse-pile-up-identification-and-re.pdf
Boyut:
599.59 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale dosyası / Article file