Test of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)

dc.contributor.authorLuo, X. L.
dc.contributor.authorModamio, V.
dc.contributor.authorNyberg, J.
dc.contributor.authorValiente-Dobon, J. J.
dc.contributor.authorNishada, Q.
dc.contributor.authorde Angelis, G.
dc.contributor.authorAgramunt, J.
dc.contributor.authorEgea, F. J.
dc.contributor.authorErduran, Mustafa Nizamettin
dc.contributor.authorErturk, S.
dc.contributor.authorde France, G.
dc.contributor.authorGadea, A.
dc.contributor.authorGonzalez, V.
dc.contributor.authorHueyuek, T.
dc.contributor.authorJaworski, G.
dc.contributor.authorMoszynski, M.
dc.contributor.authorDi Nitto, A.
dc.contributor.authorPalacz, M.
dc.contributor.authorSoederstroem, P. -A.
dc.contributor.authorSanchis, E.
dc.contributor.authorTriossi, A.
dc.contributor.authorWadsworth, R.
dc.contributor.authorErduran, Mustafa Nizamettin
dc.date.accessioned2019-08-31T12:10:23Z
dc.date.accessioned2019-08-13T09:37:57Z
dc.date.available2019-08-31T12:10:23Z
dc.date.available2019-08-13T09:37:57Z
dc.date.issued2014en_US
dc.departmentMühendislik ve Doğa Bilimleri Fakültesien_US
dc.descriptionWOS: 000344994600012en_US
dc.description.abstractA comparative study of the neutron-gamma discrimination performance of a liquid scintillator detector BC501A coupled to four different 5 in photomultiplier tubes (ET9390kb, R11833-100, XP4512 and R4144) was carried out Both the Charge Comparison method and the Integrated Rise-Time method were implemented digitally to discriminate between neutrons and gamma rays emitted by a Cf-252 source. In both methods, the neutron-gamma discrimination capabilities of the four photomultiplier tubes were quantitatively compared by evaluating their figure-of-merit values at different energy regions between 50 keVee and 1000 keVee. Additionally, the results were further verified qualitatively using time-of-flight to distinguish gamma rays and neutrons. The results consistently show that photomultiplier tubes R11833-100 and ET9390kb generally perform best regarding neutron-gamma discrimination with only slight differences in figure-of-merit values. This superiority can be explained by their relatively higher photoelectron yield, which indicates that a scintillator detector coupled to a photomultiplier tube with higher photoelectron yield tends to result in better neutron-gamma discrimination performance. The results of this work will provide reference for the choice of photomultiplier tubes for future neutron detector arrays like NEDA. (C) 2014 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipSwedish Research Council; UK STFC; Generalitat Valenciana, Spain [PROMETEO/2010/101]; MINECO, Spain [AIC-D-2011-0746, FPA2011-29854, FPA2012-33650]; Chinese Scholarship Council (CSC); Science and Technology Facilities Council [ST/L005735/1, ST/J000124/1]en_US
dc.description.sponsorshipThis work was partly funded by the Swedish Research Council, by the UK STFC, and by the Generalitat Valenciana, Spain, under Grant PROMETEO/2010/101, and by MINECO, Spain, under Grants AIC-D-2011-0746, FPA2011-29854 and FPA2012-33650. X. L. Luo acknowledges the support of the Chinese Scholarship Council (CSC).en_US
dc.identifier.doi10.1016/j.nima.2014.08.023
dc.identifier.endpage91en_US
dc.identifier.issn0168-9002
dc.identifier.issn1872-9576
dc.identifier.orcidMustafa Nizamettin Erduran |0000-0003-0852-9753en_US
dc.identifier.scopusqualityQ2
dc.identifier.startpage83en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.nima.2014.08.023
dc.identifier.urihttps://hdl.handle.net/20.500.12436/1089
dc.identifier.volume767en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorErduran, Mustafa Nizamettin
dc.language.isoen
dc.publisherElsevier Science BVen_US
dc.relation.ispartofNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipmenten_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDigital neutron-gamma discriminationen_US
dc.subjectLiquid scintillatoren_US
dc.subjectPhotomultiplier tubeen_US
dc.subjectCharge Comparisonen_US
dc.subjectIntegrated rise-timeen_US
dc.subjectTime-of-flighten_US
dc.subjectNEDAen_US
dc.titleTest of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)en_US
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublicationf15c7b3b-1513-45ba-ba89-0994e82a74cb
relation.isAuthorOfPublication.latestForDiscoveryf15c7b3b-1513-45ba-ba89-0994e82a74cb

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
test-of-digital-neutron-gamma-discrimination-with-four-different-photomultiplier-tubes-for-the-neutron-detector-array-neda.pdf
Boyut:
3 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale dosyası / Article file