Digital pulse-timing technique for the neutron detector array NEDA
| dc.contributor.author | Modamio, V. | |
| dc.contributor.author | Valiente-Dobon, J. J. | |
| dc.contributor.author | Jaworski, G. | |
| dc.contributor.author | Hueyuek, T. | |
| dc.contributor.author | Triossi, A. | |
| dc.contributor.author | Egea, J. | |
| dc.contributor.author | Di Nitto, A. | |
| dc.contributor.author | Soederstroem, P. -A. | |
| dc.contributor.author | Agramunt Ros, J. | |
| dc.contributor.author | de Angelis, G. | |
| dc.contributor.author | de France, G. | |
| dc.contributor.author | Erduran, Mustafa Nizamettin | |
| dc.contributor.author | Erturk, S. | |
| dc.contributor.author | Gadea, A. | |
| dc.contributor.author | Gonzalez, V. | |
| dc.contributor.author | Kownacki, J. | |
| dc.contributor.author | Moszynski, M. | |
| dc.contributor.author | Nyberg, J. | |
| dc.contributor.author | Palacz, M. | |
| dc.contributor.author | Sanchis, E. | |
| dc.contributor.author | Wadsworthm, R. | |
| dc.contributor.author | Erduran, Mustafa Nizamettin | |
| dc.date.accessioned | 2019-08-31T12:10:23Z | |
| dc.date.accessioned | 2019-08-13T09:37:55Z | |
| dc.date.available | 2019-08-31T12:10:23Z | |
| dc.date.available | 2019-08-13T09:37:55Z | |
| dc.date.issued | 2015 | en_US |
| dc.department | Mühendislik ve Doğa Bilimleri Fakültesi | en_US |
| dc.description | WOS: 000348040900011 | en_US |
| dc.description.abstract | A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in by 5 in BC501A liquict scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CM algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes. (C) 2014 Elsevier B.V. All rights reserved. | en_US |
| dc.description.sponsorship | Generalitat Valenciana, Spain [PROMETEO/2010/101, PROMETEO/2014/019]; MINECO, Spain [AIC-D-2011-0746, FPA2011-29854, FPA2012-33560]; STFC, UK; Swedish Research Council; Science and Technology Facilities Council [ST/J000124/1, ST/L005735/1, ST/L005727/1] | en_US |
| dc.description.sponsorship | Work partially supported by the Generalitat Valenciana, Spain, under grant PROMETEO/2010/101 and PROMETEO/2014/019, by MINECO, Spain, under grants AIC-D-2011-0746, FPA2011-29854 and FPA2012-33560, by the STFC, UK and by the Swedish Research Council. | en_US |
| dc.identifier.doi | 10.1016/j.nima.2014.12.002 | |
| dc.identifier.endpage | 76 | en_US |
| dc.identifier.issn | 0168-9002 | |
| dc.identifier.issn | 1872-9576 | |
| dc.identifier.orcid | Mustafa Nizamettin Erduran |0000-0003-0852-9753 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 71 | en_US |
| dc.identifier.uri | http://dx.doi.org/10.1016/j.nima.2014.12.002 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12436/1078 | |
| dc.identifier.volume | 775 | en_US |
| dc.identifier.wosquality | N/A | en_US |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.institutionauthor | Erduran, Mustafa Nizamettin | |
| dc.language.iso | en | |
| dc.publisher | Elsevier Science BV | en_US |
| dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Digital timing | en_US |
| dc.subject | Constant fraction discriminator | en_US |
| dc.subject | Liquid scintillator | en_US |
| dc.subject | BC501A | en_US |
| dc.subject | Neutron detector | en_US |
| dc.subject | NEDA | en_US |
| dc.title | Digital pulse-timing technique for the neutron detector array NEDA | en_US |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | f15c7b3b-1513-45ba-ba89-0994e82a74cb | |
| relation.isAuthorOfPublication.latestForDiscovery | f15c7b3b-1513-45ba-ba89-0994e82a74cb |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- Modamio-2015-Digital-pulse-timing-technique-for-.pdf
- Boyut:
- 526.37 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Makale Dosyası / Article File









