Measurement of power line sagging using sensor data of a power line inspection robot

dc.contributor.authorZengin, Aydın Tarık
dc.contributor.authorErdemir, Gökhan
dc.contributor.authorAkinci, Tahir Cetin
dc.contributor.authorSeker, Serhat
dc.date.accessioned2020-12-20T06:49:45Z
dc.date.available2020-12-20T06:49:45Z
dc.date.issued2020
dc.departmentMühendislik ve Doğa Bilimleri Fakültesi
dc.descriptionWOS:000541127800022
dc.description.abstractThe operation of energy transmission lines with high efficiency without failure has great importance in today & x2019;s electricity-dependent world. Problems that may occur in electricity transmission lines are failure cause of many operations not only industrial but also daily life. One of the most important causes of the problems encountered in power lines is the change in the amount of sagging. The change of sagging amount causes line breaks and losing energy efficiency. This problem, which is frequently encountered due to seasonal and climatic changes, is one of the major problems of continuity in the power line. The calculation of sag contains uncertain and variable parameters that can change seasonally, climatically and/or structurally such as weight per unit length of the conductor, the horizontal component of tension, total tension, etc. In this case, it is difficult to calculate a precise and reliable sag amount. The sagging of power lines is generally calculated theoretically or measured on-site by the personnel in charge. In this study, a new approach is presented to measure the sag amount by using sensor data of a power line inspection robot, precisely and reliably. The inspection robot moving on the power line can be remotely controlled and send sensor data. The sagging is measured with an error of less than 2 percent in the laboratory test field by using this technique.
dc.identifier.doi10.1109/ACCESS.2020.2998154
dc.identifier.endpage99204
dc.identifier.issn2169-3536
dc.identifier.orcidGökhan Erdemir |0000-0003-4095-6333
dc.identifier.orcidAydın Tarık Zengin |0000-0002-0860-4509
dc.identifier.scopusqualityQ1
dc.identifier.startpage99198
dc.identifier.urihttps://doi.org/10.1109/ACCESS.2020.2998154
dc.identifier.urihttps://hdl.handle.net/20.500.12436/1808
dc.identifier.volume8
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorErdemir, Gökhan
dc.institutionauthorZengin, Aydın Tarık
dc.language.isoen
dc.publisherIeee-Inst Electrical Electronics Engineers Inc
dc.relation.ispartofIeee Access
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectPower transmission lines
dc.subjectRobot sensing systems
dc.subjectTransmission line measurements
dc.subjectInspection
dc.subjectMathematical model
dc.subjectConductors
dc.subjectPower line inspection
dc.subjectline sag
dc.subjectline inspection robot
dc.titleMeasurement of power line sagging using sensor data of a power line inspection robot
dc.typeArticle
dspace.entity.typePublication

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Zengin-2020-Measurement-of-power-line-sagging-u.pdf
Boyut:
6.89 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale dosyası / Article file