A contribution to structural reliability analysis of composite high-pressure hydrogen storage tanks

dc.contributor.authorAmer, Youcef Sid
dc.contributor.authorBenammar, Samir
dc.contributor.authorTee, Kong Fah
dc.contributor.authorWadi, Mohammed
dc.contributor.authorJouda, Mohammed S.
dc.contributor.authorWadi, Mohammed
dc.contributor.authorJouda, Mohammed
dc.date.accessioned2024-07-17T08:01:38Z
dc.date.available2024-07-17T08:01:38Z
dc.date.issued2023
dc.departmentMühendislik ve Doğa Bilimleri Fakültesi
dc.description.abstractAlthough composite high-pressure tanks are a subject of growing interest, especially for hydrogen storage applications, a detailed structural reliability analysis still needs to be improved. This work aims to provide a probabilistic investigation of the mechanical response of composite high-pressure hydrogen storage tanks using the Monte Carlo Simulation method. A performance function based on the circumferential model of composite pressure cylinders is employed with five random design variables. According to the results, the internal pressure and the helical layer thickness are the foremost parameters significantly impacting the structural reliability of the tank, whereas, the helical layer thickness and winding angles have a minor influence. In addition, high coefficients of variation values cause the contraction of the safety margin potentially leading to the failure of the composite hydrogen high-pressure tank. The obtained results were validated with experimental tests available in the literature.
dc.identifier.citationSid Amer, Y., Benammar, S., Fah Tee, K., Wadi, M., & Jouda, M. S.. (2023). A contribution to structural reliability analysis of composite high-pressure hydrogen storage tanks. Journal of Konbin, 53(2), 33–44. https://doi.org/10.5604/01.3001.0053.7104
dc.identifier.doi10.5604/01.3001.0053.7104
dc.identifier.endpage44
dc.identifier.issn2083-4608
dc.identifier.issn1895-8281
dc.identifier.issue2
dc.identifier.orcid0000-0001-9435-603X
dc.identifier.orcid0000-0003-2344-3894
dc.identifier.orcid0000-0003-3202-873X
dc.identifier.orcid0000-0001-8928-3729
dc.identifier.orcid0000-0002-7364-5059
dc.identifier.startpage33
dc.identifier.urihttps://doi.org/10.5604/01.3001.0053.7104
dc.identifier.urihttps://hdl.handle.net/20.500.12436/6170
dc.identifier.volume53
dc.institutionauthorWadi, Mohammed
dc.institutionauthorJouda, Mohammed
dc.language.isoen
dc.publisherWarsaw "Versita"
dc.relation.ispartofJournal of KONBiN
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectStructural reliability
dc.subjectComposite tanks
dc.subjectHydrogen storage
dc.subjectMonte Carlo simulation
dc.subjectsafety margin
dc.titleA contribution to structural reliability analysis of composite high-pressure hydrogen storage tanks
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublicatione57e2394-09f4-4128-bdb4-84c708867a9f
relation.isAuthorOfPublication836815e7-0bc9-4212-a7d2-4e3da720641f
relation.isAuthorOfPublication.latestForDiscoverye57e2394-09f4-4128-bdb4-84c708867a9f

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
2144951.pdf
Boyut:
1.86 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale dosyası / Article file

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: