Protection coordination in electrical substation part-2 unit protections (differential and distance protection) -case study of Siddik Kardesler Substation (SKS), Istanbul, Turkey

dc.authorwosidAAU-2662-2020
dc.authorwosidV-5463-2019
dc.authorwosidABG-8088-2020
dc.authorwosidAAE-8198-2020
dc.contributor.authorShobole, Abdulfetah
dc.contributor.authorWadi, Mohammed
dc.contributor.authorWadi, Mohammed
dc.contributor.authorTur, Mehmet Rida
dc.contributor.authorWadi, Mohammed
dc.contributor.authorShobole, Abdulfetah Abdela
dc.date.accessioned2019-08-31T12:10:23Z
dc.date.accessioned2019-08-13T09:37:46Z
dc.date.available2019-08-31T12:10:23Z
dc.date.available2019-08-13T09:37:46Z
dc.date.issued2017en_US
dc.departmentMühendislik ve Doğa Bilimleri Fakültesien_US
dc.descriptionWOS: 000418818000014en_US
dc.description.abstractPower systems must be protected against faults to ensure quality and reliable generation, transmission and distribution of power systems. Power system protection is provided by the protection relays. This paper is the second part of the Protection Coordination study for the Siddik Kardesler Substation. The protection for transmission lines, transformer, bus bars and customer feeders is provided by overcurrent protection, differential and distance protection schemes. In this paper, issues related to the Differential Protection and Distance Protection for the substation will be discussed. Finally, the test and commissioning have been conducted and the substation is successfully energized without a problemen_US
dc.identifier.citationShobole, A., Baysal, M., Wadi, M., & Tur, M. R. (2017). Protection coordination in electrical substation part-2 unit protections (differential and distance protection)-case study of Siddik Kardesler Substation (SKS), Istanbul, Turkey. Gazi University Journal of Science.
dc.identifier.endpage178en_US
dc.identifier.issn2147-1762
dc.identifier.issue4en_US
dc.identifier.orcid0000-0002-6298-918Xen_US
dc.identifier.orcid0000-0002-3180-6504
dc.identifier.orcid0000-0001-8928-3729
dc.identifier.startpage163en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12436/1026
dc.identifier.volume30en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Science
dc.institutionauthorShobole, Abdulfetah
dc.institutionauthorBaysal, Mustafa
dc.language.isoen
dc.publisherGazi Üniversitesien_US
dc.relation.ispartofGazi University Journal of Scienceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDifferential Protectionen_US
dc.subjectDistance Protectionen_US
dc.subjectProtection Coordinationen_US
dc.subjectRED 615en_US
dc.subjectMiCOMho P443en_US
dc.titleProtection coordination in electrical substation part-2 unit protections (differential and distance protection) -case study of Siddik Kardesler Substation (SKS), Istanbul, Turkeyen_US
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublicatione57e2394-09f4-4128-bdb4-84c708867a9f
relation.isAuthorOfPublication4fd5b879-7f50-4336-a18f-5f6e6c324855
relation.isAuthorOfPublication.latestForDiscoverye57e2394-09f4-4128-bdb4-84c708867a9f

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
380290.pdf
Boyut:
954.62 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası / Article File