Geant4 simulation of a conceptual calorimeter based on secondary electron emission
Yükleniyor...
Dosyalar
Tarih
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
IOP PUBLISHING LTD
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
We present a conceptual sampling electromagnetic calorimeter based on secondary electron emission process. The secondary electron emission process was implemented in Geant4 as a user physics class, which accurately reproduces the energy spectrum and yield of secondary electrons for thin metals. The simulation results for the response linearity and energy resolution are compared with that of a scintillation calorimeter. The response and energy resolution of the calorimeter were obtained for electron energies up to 50 GeV. The response linearity to electromagnetic showers is to within 1.5%, whereas the energy resolution is sigma/E = (44%) GeV1/2/root E for 2.5 cm sampling of iron absorber.
Açıklama
WOS: 000406392600014
Anahtar Kelimeler
Detector modelling and simulations II (electric fields, charge transport, multiplication, and induction, pulse formation, electron emission, etc), Calorimeter methods, Electron multipliers (vacuum), Vacuum-based detectors
Kaynak
Journal of Instrumentation
WoS Q Değeri
Scopus Q Değeri
Cilt
12